Join the 155,000+ IMP followers

www.electronics-usa.com

Contactless Medical-Grade Temperature Sensor for Smart Wearables

Melexis introduces the MLX90636, a 1.8 × 1.8 mm far-infrared sensor with ±0.2 °C accuracy for wrist-worn devices and core body temperature research.

  www.melexis.com
Contactless Medical-Grade Temperature Sensor for Smart Wearables

Health-monitoring wearables are moving towards deeper health insights, which increases demand for precise, non-contact thermal sensing in very small devices. Contact thermometers remain susceptible to ambient temperature noise and thermal lag, while far-infrared (FIR) thermometry in a surface-mount device (SMD) package measures skin surface temperature without these effects. Melexis addresses this requirement with the MLX90636, a contactless temperature sensor that the company describes as the world’s smallest delivering medical accuracy, intended for potential use in wearable digital health devices.

Thermal design challenges in miniature FIR sensors
Developing a stable FIR temperature sensor in an ultra-miniature package presents major thermal management challenges, as the sensor itself is exposed to rapid ambient temperature changes and air turbulence in a wrist-worn device. The MLX90636 is designed to remain robust against these influences while maintaining measurement accuracy. It builds on the MLX90632, Melexis’ earlier SMD FIR sensor.

Technical specifications of the MLX90636
The sensor is housed in a chip-scale package measuring 1.8 × 1.8 × 0.75 mm³, targeting space-constrained smartwatches, fitness bands and smart rings. It is factory-calibrated to an accuracy of ±0.2 °C within the human body temperature range, specified in accordance with ASTM E1965-98 (re-approved 2009), section 5.4, the standard specification for infrared thermometers for intermittent determination of patient temperature.

For continuous battery-operated monitoring, the sleep current is below 2.5 µA and the refresh rate is programmable from 0.5 Hz to 32 Hz, allowing designers to balance measurement frequency against power consumption. System integration is supported by dual 2.8 V or 3.3 V supply options, an I²C interface with a software-definable address pin, integrated post-calibration options and open-source driver support on GitHub. The MLX90636 is available.

From wrist temperature to core body temperature
Wrist skin temperature alone does not yield core body temperature (CBT), because skin readings are influenced by local blood flow, ambient conditions and device thermals. As part of its technology roadmap, Melexis is researching wrist-to-core modelling to track CBT from wrist-worn sensor inputs. To support exploratory feasibility studies, the company is finalising an evaluation kit for assessing core body temperature performance with potential customers.

“Accurate skin temperature measurement at the wrist is only part of the challenge,” said Joris Roels, Marketing Manager at Melexis. “By conducting further research related to the application of our latest sensor, we aim to enable core body temperature estimation.”

Additional Context
This section details technical specifications and competitive benchmarking not included in the original product announcement.

The predecessor MLX90632 is supplied in a 3 × 3 × 1 mm package. With a volume of about 2.4 mm³ compared with about 9 mm³, the MLX90636 package is roughly 70% smaller, which is relevant for devices such as smart rings where available board area and height are particularly limited.

FIR thermometry determines temperature from the infrared radiation emitted by a surface, so the measurement is not affected by thermal contact resistance or the heat capacity of a contact probe. Its accuracy instead depends on the stability of the sensor’s own thermal reference, which is why resistance to ambient temperature changes is a key design parameter for wearable FIR sensors. No independent benchmark data are available for an objective comparison with miniature FIR temperature sensors from other manufacturers.